Reynolds Number

Reynolds number Re = ρvL/μ, or vL/ν from kinematic viscosity, in SI units with water and air presets, labeled laminar, transitional or turbulent for pipe flow. How it works

Use the Reynolds Number

Fills density and viscosity. Typing in either field switches back to Custom.

Reynolds number (Re)
100,000
Regime Turbulent flow

Re = density × velocity × length ÷ dynamic viscosity, or velocity × length ÷ kinematic viscosity (kinematic viscosity is dynamic viscosity ÷ density, so the two forms agree). Shown to 6 significant digits.

Water rows come from a handbook table (CRC Handbook / IAPWS-based, interpolated); air is at 20 °C and 1 atm. Real fluids vary with temperature and composition, so check your own figures for critical work.

The regime label uses the limits for flow in a full circular pipe with the diameter as the length: laminar below 2,300, transitional from 2,300 to 4,000, turbulent above 4,000. The critical Reynolds number is different for every geometry, so for flow over a flat plate, around a sphere or a hull, or in an open channel the number is the same formula but the label does not apply (a flat-plate boundary layer, for example, turns turbulent near 500,000). For a non-circular duct use the hydraulic diameter as the length.

About the Reynolds Number

Water at 20 °C moving at 0.1 m/s through a 50 mm pipe has a Reynolds number of 4,983.08, just above the turbulent limit of 4,000. Re = ρvL ÷ μ: density times velocity times pipe diameter, divided by dynamic viscosity. This Reynolds number calculator labels the result laminar below 2,300, transitional from 2,300 to 4,000 and turbulent above 4,000, the usual limits for flow in a pipe.

Reynolds numbers for water and air

FluidDensity (kg/m³)Viscosity (Pa·s)Velocity (m/s)Length (m)RePipe-flow label
Water, 20 °C998.210.00100160.020.05996.615Laminar
Water, 20 °C998.210.00100160.0460.052,292.22Laminar
Water, 20 °C998.210.00100160.050.052,491.54Transitional
Water, 20 °C998.210.00100160.080.053,986.46Transitional
Water, 20 °C998.210.00100160.10.054,983.08Turbulent
Water, 20 °C998.210.001001610.0549,830.8Turbulent
Water, 20 °C998.210.001001610.199,661.5Turbulent
Water, 10 °C999.700.00130600.10.053,827.34Transitional
Water, 60 °C983.200.00046600.10.0510,549.4Turbulent
Air, 20 °C, 1 atm1.2040.000018130.50.01332.046Laminar
Air, 20 °C, 1 atm1.2040.0000181320.056,640.93Turbulent
Air, 20 °C, 1 atm1.2040.00001813100.166,409.3Turbulent
Air, 20 °C, 1 atm1.2040.000018133011,992,280Turbulent

Fluid properties from The Engineering ToolBox tables: water density 999.70, 998.21 and 983.20 kg/m³ and viscosity 0.0013060, 0.0010016 and 0.0004660 Pa·s at 10, 20 and 60 °C; air at 20 °C and 1 atm 1.204 kg/m³ and 18.13 µPa·s. The tool’s own fluid presets use slightly different handbook figures (water at 20 °C 0.001002 Pa·s, air 0.00001825 Pa·s), so with a preset the 0.1 m/s water row gives 4,981.09. The label assumes flow inside a full circular pipe with L as its diameter.

Frequently asked questions

What Reynolds number is laminar flow?
In a full circular pipe, flow is laminar below about 2,300 and turbulent above 4,000 by the usual engineering limits; in between it can switch back and forth. Those limits are a convention: Wikipedia’s article gives turbulent flow from about 2,900 for fully developed pipe flow. The calculator labels by 2,300 and 4,000.
What is the Reynolds number of air?
It depends on speed and size. With air at 20 °C (1.204 kg/m³, 0.00001813 Pa·s), 10 m/s over 0.1 m gives 66,409.3, while 0.5 m/s in a 10 mm tube gives 332.046.
Does water temperature change the Reynolds number?
Yes, mainly through viscosity, which falls as water warms. In a 50 mm pipe at 0.1 m/s, Re is 3,827.34 at 10 °C (transitional), 4,983.08 at 20 °C and 10,549.4 at 60 °C (both turbulent).
Do the 2,300 and 4,000 limits apply to a plate, a hull or a river?
No. The critical Reynolds number is different for every geometry; a boundary layer on a flat plate turns turbulent near 500,000, measured from the leading edge. Use the number for those cases, but not the pipe-flow label.
What units does it use?
SI only: density in kg/m³, velocity in m/s, length in m and dynamic viscosity in Pa·s, or kinematic viscosity in m²/s. Viscosity in centipoise divides by 1,000 (1 cP = 0.001 Pa·s), and centistokes by 1,000,000 to give m²/s. For a non-circular duct, enter the hydraulic diameter as the length. Every value must be above 0.
Can I use kinematic viscosity instead?
Yes. Set Viscosity given as to kinematic and Re = v × L ÷ ν, with no density field. Switching converts the typed value with ν = μ ÷ ρ. With ν = 0.000001 m²/s (about water at 20 °C), 1 m/s in a 50 mm pipe gives 50,000. The presets fill both forms: air at 20 °C is 0.000015158 m²/s.